OSH-Calc Pro License
This clinical workstation requires a personal licence code to activate the Malaysian DOSH Medical Surveillance modules.
Spirometry Parameters
Actual and predicted lung volumes in Litres (L)
Calculated Ratios & Gates
Live DOSH surveillance threshold analysis
Volume-Time Spirogram
Predicted vs actual curve · FEV1 at t = 1.0 s · schematic exponential fit, not a recorded trace
Enter worker spirometric parameters (FEV1 and FVC actual & predicted) to calculate fitness to work.
Malaysian DOSH Surveillance Decision Tree Audit Rules ▾
OCCUPATIONAL HEALTH MEDICAL SURVEILLANCE
| Parameter | Actual (L) | Predicted (L) | % Predicted / Ratio | DOSH Reference |
|---|---|---|---|---|
| FEV1 (Forced Expiratory Vol, 1s) | - | - | - | Severity benchmark |
| FVC (Forced Vital Capacity) | - | - | - | Normal: ≥ 80.0% |
| FEV1 / FVC Ratio | - | - | Normal: ≥ 70.0% | |
Right Ear (AD)
Red Channel • Standard EarLeft Ear (AS)
Blue Channel • Standard EarPure Tone Audiogram
Right ear ○ solid red · Left ear ✕ dashed blue · baseline in grey · DOSH STS 2-4 kHz highlighted
Enter baseline and current hearing thresholds to compute Standard Threshold Shift (STS) and fitness status.
Malaysian DOSH Occupational Noise Exposure Rules STS Rules ▾
OCCUPATIONAL HEALTH MEDICAL SURVEILLANCE
| Channel / Frequency | Baseline (dB) | Current (dB) | Shift (2-4k) | Impairment (1-3k) |
|---|---|---|---|---|
| Right Ear (AD) | - | - | - | - |
| Left Ear (AS) | - | - | - | - |
Methylhippuric Acids (MHA)
Xylene / Toluene metabolite • Ceiling 1.50 g/g creatinine
S-Phenylmercapturic (S-PMA)
Benzene metabolite • Carcinogen surveillance • Ceiling 500 µg/g
Blood Lead Level (BLL)
Inorganic lead • Medical Removal Protection (MRP) ceiling 50.0 µg/dL
Enter worker biological monitoring biomarkers to evaluate statutory chemical fitness under USECHH Schedule II.
General Physical Examination
Blood pressure & statutory occupational safety screening
HR Clearance Metadata
Job role & statutory examining doctor certification details
DOSH MEDICAL SURVEILLANCE - FITNESS TO WORK CERTIFICATE
| Worker ID: | - | Designation / Role: | - |
| Surveillance Standard: | DOSH Malaysia (USECHH Regs 2000 & Noise Exposure Regs 2019) | ||
| Examination Module | Key Parameters / Thresholds | Module Determination |
|---|---|---|
| Occupational Spirometry | - | - |
| Pure Tone Audiometry (STS) | - | - |
| Physical Exam & Screening | - | - |
- Fit for designated operational duties without clinical restrictions.
I hereby certify that the worker identified above has undergone statutory medical surveillance assessment. The determination recorded above strictly reflects medical suitability for the designated job role under Malaysian DOSH guidelines.
Settings
Device preferences & clinical standardsOccupational Safety and Health Act (OSHA 1994), USECHH Regulations 2000 & Occupational Noise Exposure Regulations 2019.
- Spirometry: Ratio Gate 70.0%, FVC Gate 80.0%, FEV1 Severity Bands (80%, 50%, 30%).
- Audiometry (STS): Gate 1 Shift ≥ 10.0 dB (2k, 3k, 4k avg), Gate 2 Hearing Impairment > 25.0 dB (1k, 2k, 3k avg). Worst ear principle.
- Zero-PII Architecture: No patient identifiable information stored or transmitted.
- 100% Offline Progressive Web App with deterministic local calculations.
-